Type | Oil cooler |
---|---|
Application | The FCU is installed directly on the tank. It saves on space and piping processes. The U- shaped tubing makes it ideal for high temperatures. |
Features |
・Original φ9 low fin tube enables high performance and downsizing. ・Choose from 3 model types for all sizes for large and small oil flow rates. |
⇈ You can select heat exchanger simply by the catalog.
Item | Standard Spec. | Option |
---|---|---|
Type | Tank insert type, U-shaped tube | |
Maximum working pressure | Shell side: 1.0MPa Tube side: 1.0MPa |
|
Corresponding fluid | Shell type: Mineral oil Tube type: Freshwater |
Shell side: Water glycol oil, Fatty ester oil, etc. |
Cooling tube | Specifications: φ9 low- finned tube Material quality: Phosphorus deoxidized copper |
|
Heat transfer area | 0.4-2.8㎡ | |
Tie-in | Shell side: Rc threaded type Tube side: Rc threaded type |
Code | Fluid type |
- | Mineral oil |
G | Water glycol oil |
Fatty acid ester oil |
Code | Heat transfer area (㎡) | Shell dia. |
108A | 0.4 |
φ90 |
114A | 0.7 | |
122A | 1.1 | |
226A | 1.3 |
φ114.3 (100A) |
234A | 1.7 | |
242A | 2.1 | |
256A |
2.8 |
Code | Oil quantity classification *1 |
0 | Large |
1 | Normal |
2 |
Small |
Oil quantity classification
*1 Flow rate classification is basically as follows.
・large oil rate is model with small number
・small oil rate is model with large number
Model example:G-FCU-256A-1
+81-3-6912-9922+81-3-6912-9922
Excluding Saturdays, Sundays and Holidays