Type | Oil cooler |
---|---|
Application | Built in thermostat automatically controls cooling water and keeps temperature setting. |
Features |
・Valve opening temperature of thermostat is selectable 40℃ (special), 45℃ (special), 51℃ (standard). ・Original φ9 low fin tube enables high performance and downsizing. ・Choose from 3 model types for all sizes for large and small oil flow rates. ・High flexbility of installation by selectable flow direction and adjustable U-bolt stand. |
Item | Standard Spec. | Option |
---|---|---|
Type | Floating tube sheet tube | |
Maximum working pressure | Shell side: 1.0MPa Tube side: 0.7MPa |
|
Corresponding fluid | Shell side: Mineral oil Tube side: Freshwater |
Shell side: Water glycol oil, fatty ester oil, phosphate ester oil, etc. |
Cooling tube | Specifications: φ9 low- finned tube Material quality: Phosphorus deoxidized copper |
|
Heat transfer area | 2.5-5.5㎡ | |
Tie-in | Shell side: Rc threaded type Tube side: Rc threaded type |
|
Thermostat | Inlet oil: 51℃ | Inlet oil: selectaable 40℃, 45℃ |
Code | Fluid type |
- | Mineral oil |
G | Water glycol oil |
Fatty ester oil | |
F | Phosphate ester oil |
W | G+F |
Code | Heat transfer area (㎡) | Shell dia. |
350A | 2.5 |
φ139.8 (125A) |
370A | 3.5 | |
390A | 4.5 | |
311A | 5.5 |
Code | Oil quantity classification *1 |
0 | Large |
1 | Normal |
2 | Small |
Code | Oil Inlet Temperature | |
None | 51℃ | standard |
40 | 40℃ | special spec |
45 | 45℃ |
Oil quantity classification
*1 Flow rate classification is basically as follows.
・large oil rate is model with small number
・small oil rate is model with large number
*2 Valve opening temperature
Standard operating temperature is 51℃.
Please contact us price and delivery when operating
temperature is 40℃ and 45℃ because of non-standard model.
Model example:FCW-370A-2
+81-3-6912-9922+81-3-6912-9922